1 Western Digital defines a megabyte (MB) as 1,000,000 bytes and a gigabyte (GB) as 1,000,000,000 bytes 2 Turning the system power off causes the WD Caviar® to perform an automatic head park operation.
Spindle Start Time
- From Power-on to Drive Ready 1
- From Power-on to Rotational Speed 2
6.0 s average
4.5 s average
Contact Start/Stop Cycles (CSS)
50,000 minimum
1 Defined as the time from power-on to the setting of the Drive Ready and Seek Complete including calibration. 2 Defined as the time from power-on to when the full spindle rotational speed is reached.
Linear: 5-500 Hz, 0.25 G (0 to peak)
Random: 10-300 Hz, 0.004 g2/Hz
Non-operating
5-20 Hz, 0.195 inches (double amplitude) 20-500 Hz, 4.0 G (0 to peak)
Sweep Rate
0.5 octave/minute minimum
Drive Generated Vibration
Operating
0.4 gm-mm typical with the drive in an unconstrained condition
Rotational Shock Non-Operating
Amplitude
20 K rad/sec2
Duration
2 ms
Operating Temperature and Humidity
Temperature
5°C to 55°C (41°F to 131°F) 5°C to 65°C (case temp)
Humidity
5-85% RH non-condensing 33°C (maximum wet bulb)
Thermal Gradient
20°C/hour (maximum)
Humidity Gradient
20%/hour (maximum)
Non-Operating Temperature and Humidity
Temperature
-40°C to 60°C (-40°F to 140°F)
Humidity
5-95% RH non-condensing 33°C (maximum wet bulb)
Thermal Gradient
30°C/hour (maximum)
Humidity Gradient
20%/hour (maximum)
Altitude
Operating
-1000 feet to 10,000 feet (-305M to 3,050M)
Non-Operating
-1000 feet to 40,000 feet (-305M to 12,200M)
Acoustics
Idle Mode 2
35 dBA average
Seek Mode 0 3
38 dBA average
Seek Mode 3 3
35 dBA average
Reliability Specifications
AFR
<0.8%
MTBF
500,000 Power On Hours
Component Design Life
5 years
1 Half sine wave, measured without shock isolation and without non-recoverable errors. 2 No audible pure tones. 3 Random seek at a rate of 26 seeks per second.